Loading...
Thumbnail Image
Publication

The intra- and inter-day reliability of the FitroDyne as a measure of multi-jointed muscle function

Fernandes, John
Lamb, Kevin L.
Twist, Craig
Advisors
Editors
Other Contributors
EPub Date
Publication Date
2016-02-27
Submitted Date
Other Titles
Abstract
The FitroDyne has been used to assess muscle function but its reliability has not been determined during traditional multi-jointed resistance exercises. Objective: To assess the intra- and inter-day reliability of the FitroDyne during traditional resistance exercises. Methods: 14 resistance trained males completed a one repetition maximum (1RM) and three repetitions of bench press, squat and bent-over-row in 10% increments (from 20 to 80%). Replica trials were completed two and 48 hours later. The FitroDyne rotary encoder measured barbell velocity during each repetition from which power output was calculated. Results: For all loads and exercises the intra-day typical error (TE) for peak and mean power, and velocity, respectively, during bench press (8.2-53 W and 2.2-6.9 cms-1), squat (13.3-55.6 W and 2.4-7.4 cms-1), and bent-over-row (14.5-62.8 W and 4-10.5 cms-1) identified only moderate changes. Bench press yielded poor intra-day reliability at 80% 1RM only (CV% = 12.2-17.1), whereas squat and bent-over-row across all loads for peak and mean power and velocity displayed better reliability CV% = 2.4-9.0). Inter-day, the TE detected moderate changes for peak and mean power and velocity for all three exercises. Inter-day reliability was comparable to intra-day, though improved for bench press 80%1RM (CV% = 6.1-8.6). Conclusion: These data support the use of the FitroDyne at submaximal loads for monitoring moderate changes in muscle function both intra- and inter-day.
Citation
Fernandes, J., Lamb, K., & Twist, C. (2016). The intra- and inter-day reliability of the FitroDyne as a measure of multi-jointed muscle function. Isokinetics and Exercise Science, 24(1), 39-49. DOI: 10.3233/IES-150599.
Publisher
IOS Press
Journal
Isokinetics and Exercise Science
Research Unit
DOI
10.3233/IES-150599
PubMed ID
PubMed Central ID
Type
Article
Language
en
Description
Reprinted from Isokinetics and Exercise Science, Vol 24, Fernandes, J., Lamb, K., & Twist, C., The intra- and inter-day reliability of the FitroDyne as a measure of multi-jointed muscle function, pp. 39-49, Copyright (2016), with permission from IOS Press
Series/Report no.
ISSN
0959-3020
EISSN
ISBN
ISMN
Gov't Doc
Test Link
Sponsors
Additional Links
http://content.iospress.com/articles/isokinetics-and-exercise-science/ies599