Loading...
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, Mohamed H.; orcid: 0000-0002-0832-8559; email: Mohamed.hassan@manchester.ac.uk ; Vyas, Cian; orcid: 0000-0001-6030-1962; email: cian.vyas@manchester.ac.uk ; Grieve, Bruce; orcid: 0000-0002-5130-3592; email: bruce.grieve@manchester.ac.uk ; Bartolo, Paulo; orcid: 0000-0003-3683-726X; email: paulojorge.dasilvabartolo@manchester.ac.uk
Hassan, Mohamed H.; orcid: 0000-0002-0832-8559; email: Mohamed.hassan@manchester.ac.uk
Vyas, Cian; orcid: 0000-0001-6030-1962; email: cian.vyas@manchester.ac.uk
Grieve, Bruce; orcid: 0000-0002-5130-3592; email: bruce.grieve@manchester.ac.uk
Bartolo, Paulo; orcid: 0000-0003-3683-726X; email: paulojorge.dasilvabartolo@manchester.ac.uk
Advisors
Editors
Other Contributors
Affiliation
EPub Date
Publication Date
2021-07-08
Submitted Date
Collections
Other Titles
Abstract
The detection of glucose is crucial in the management of diabetes and other medical conditions but also crucial in a wide range of industries such as food and beverages. The development of glucose sensors in the past century has allowed diabetic patients to effectively manage their disease and has saved lives. First-generation glucose sensors have considerable limitations in sensitivity and selectivity which has spurred the development of more advanced approaches for both the medical and industrial sectors. The wide range of application areas has resulted in a range of materials and fabrication techniques to produce novel glucose sensors that have higher sensitivity and selectivity, lower cost, and are simpler to use. A major focus has been on the development of enzymatic electrochemical sensors, typically using glucose oxidase. However, non-enzymatic approaches using direct electrochemistry of glucose on noble metals are now a viable approach in glucose biosensor design. This review discusses the mechanisms of electrochemical glucose sensing with a focus on the different generations of enzymatic-based sensors, their recent advances, and provides an overview of the next generation of non-enzymatic sensors. Advancements in manufacturing techniques and materials are key in propelling the field of glucose sensing, however, significant limitations remain which are highlighted in this review and requires addressing to obtain a more stable, sensitive, selective, cost efficient, and real-time glucose sensor.
Citation
Sensors, volume 21, issue 14, page e4672
Publisher
MDPI
Journal
Research Unit
DOI
PubMed ID
PubMed Central ID
Type
article
Language
Description
From MDPI via Jisc Publications Router
History: accepted 2021-07-06, pub-electronic 2021-07-08
Publication status: Published
Funder: Engineering and Physical Sciences Research Council; Grant(s): EP/R513131/1
History: accepted 2021-07-06, pub-electronic 2021-07-08
Publication status: Published
Funder: Engineering and Physical Sciences Research Council; Grant(s): EP/R513131/1
